Fuse rating翻译
Web缩写 全称 中 文AC alternating current 交流电AC automatic control 自动控制ACA accident consequence assessment 事故后果评价ACB air circuit breaker 空气断路器ACC accident 故障、事故ACCUM accumulate accumulate 累计、 蓄电池ACDS acourtic cr Web电气专业毕业设计外文翻译.pdf,电气专业毕业设计外文翻译 附录1:外文资料翻译 A1.1外文资料题目 26.22 接地故障电路开关 我们目前为止报道的接地方法通常是充分的 , 但更加进一步的安全措施在某些情况下是必要的。假设 例如, 有人将他的手指伸进灯口 (如Fig.26.45示)。虽然金属封入物安全地接地 ...
Fuse rating翻译
Did you know?
Webfuse翻译:安全部件, 保險絲, 爆炸裝置, 導火索;導火線引信;信管, 結合, 熔合;結合, 熔化, (使)熔化, 停止工作, (使)(因保險絲熔斷而)停止工作。了解更多。 WebFuseology Selection Guide - Littelfuse
WebFuse rating-For protection of the device, the branch circuit protection must be secured with a maximum fuse rating of 16A. resource.boschsecurity.com. resource.boschsecurity.com. Calibres des fusibles - Pour la protection de l'appareil, la protection des circuits de dérivation doit être assurée par un fusible de 16 A maximum. WebOct 28, 2024 · Typical opening times at 500 % of the fuse ampere rating range from 0.05 second to approximately 2 seconds. Fast-acting fuses are suitable for non-inductive loads such as incandescent lighting and general-purpose feeders, or branch circuits with little or no motor load. When protecting motors and other inductive loads, fast-acting fuses must …
Webrating翻译:等級,級別;程度。了解更多。 WebThe Class L fuses are the only time-delay fuse series available in these higher ampere ratings. Information on all the Littelfuse fuse series referenced above can be found on the UL/CSA Fuse Classes and Applications Charts found in the Technical Application Guide at the end of the POWR-GARD products catalog.
WebOct 28, 2009 · Understanding fuse ratings. Abstract: Selecting a fuse is more than just about trip current. Proper fuse performance depends on many aspects of a fuse's …
WebA fuse rating is the current need to blow (break) the fuse. When a fuse has blown it removes electrical power from an electrical circuit. The fuse rating is usually on the side … how to access the active directoryWebApr 16, 2013 · Fuses have two basic ratings. The first is current rating. The current rating is the amount of current that a fuse will safely pass before blowing. When the current flow through a fuse exceeds its ... meta office los angelesWebthe fuses are the same rating, the MINI Fuse opens in about 0.1 seconds while the MAXI Fuse opens in about 2.2 seconds. When selecting a fuse, the start-up pulse should be defined and then compared to the time-current curve for the fuse. MAXI Fuse D. Current Rating The current rating is the maximum current which the fuse can meta office malaysiaWebA fuse rating is the current need to blow (break) the fuse. When a fuse has blown it removes electrical power from an electrical circuit. The fuse rating is usually on the side of the fuse. The fuse rating is usually defined in 'amps' – amps are the unit of measurement of electrical current. Suggest Corrections. meta office in usaWebtime-current characteristics of the fuses. The correct current rating of fuse is then chosen as being the one immediately to the right of the point so plotted. The chosen fuse must also have a current rating of at least 1.3 times the full-load current of the associated motor. The rating thus chosen will be adequate for normal applica- how to access the azure cliWebvoltage, unless otherwise stated on the fuse. For example, the FLSR_ID indicating fuse has a voltage rating of 75–600 volts. This fuse can be used on 600 volts, 480 volts, 250 … meta office nycWebOct 3, 2024 · There is an entire section on the Digi-Key website for fuse kits titled “ Circuit Protection Kits - Fuse ”. An example is the 0034.9871 from Schurter, Inc. which comes with 180 individual 5 mm x 20 mm fuses ranging from 800 mA to 10 A. Figure 12 depicts the 0034.9871. Figure 12: Schurter’s 0034.9871 fuse kit. how to access the bing chat